Mainly supply CNC system and CNC parts of Siemens, FANUC and Mitsubishi to the customers worldwide

Mainly supply CNC system and CNC parts of Siemens, FANUC and Mitsubishi to the customers worldwide

SIEMENS SINAMIC G110 Converters

  • PRODUCT DETAIL

Overview

SINAMICS G110, frame size FSA (right with flat heat sink)

SINAMICS G110, frame sizes FSB and FSC

SINAMICS G110 is a converter with basic functions for a wide range of industrial drive applications with variable speeds.

The extremely compact SINAMICS G110 converter operates with voltage-frequency control from 200 V to 240 V on single-phase line supply systems.

It is the ideal "price-conscious" converter solution in the lower power range of the SINAMICS product family.

The following line-side power components are available for SINAMICS G110 converters:

  • EMC filters
  • Line reactors
  • Fuses
  • Circuit breaker

The accessories listed below are also available:

  • Operator panel
  • Mounting accessories
  • Commissioning tool

and offline in the DT Configurator integrated in Catalog CA 01 as an add-on on DVD‑ROM. In addition, the DT Configurator can be used on the Internet without requiring any installation. The Drive Technology Configurator (DT Configurator) can be found in the Siemens Industry Mall at the following address:

Benefits

  • Simple installation, configuration, and commissioning
  • Robust EMC design
  • Extensive parameter range enables configurations for a wide range of applications
  • Simple cable connection
  • Scalable functionality with analog and USS versions
  • Quiet motor operation as a result of the high pulse frequency
  • Status information and alarms via the optional BOP (Basic Operator Panel)
  • Rapid copying of parameters via the optional BOP
  • External options for PC communication and BOP
  • Fast response time of the digital inputs with a high degree of reproducibility for applications demanding fast responses
  • Precise setpoint input using a high-resolution 10-bit analog input (analog versions only)
  • LED for status information
  • Variants with integrated EMC filter class A or B
  • DIP switches for easy adaptation to 50 Hz or 60 Hz applications
  • DIP switches for simple bus termination for the USS version (RS485)
  • Bus-capable serial RS485 interface (USS versions only) enables integration into a networked drive system
  • 2/3-wire method (pulsed/maintained signals) for universal control via digital inputs
  • Adjustable lower voltage limit for the DC link to ensure controlled motor braking if the power fails
Accessories (overview)
  • BOP operator panel
  • Adapter for mounting on DIN rails (frame sizes FSA and FSB)
  • PC converter connection kit
  • STARTER commissioning tool
Line-side power components (overview)
  • EMC filter, class B with low leakage currents
    (additionally available for converters with integrated filter)
  • EMC filter, class B
    (additionally available for converters with integrated filter)
  • Line reactors
International standards
  • Fulfills the requirements of the EU low-voltage guideline
  • CE marking
  • Certified to UL and cUL
  • C-Tick
  • Design
  • The SINAMICS G110 standard converters are equipped with a control module and a power module, providing the converter in the CPM 110 version (Controlled Power Module) with a compact and efficient design. They operate with the latest IGBT technology and digital microprocessor control.
  • The SINAMICS G110 converter product range consists of the following variants and versions:

    • The analog variant is available in the following versions:
      • Without EMC filter, with heat sink
      • With integrated EMC filter, class A/B, with heat sink
      • Without EMC filter, with flat heat sink (FSA frame size only)
      • With integrated EMC filter, class B, with flat heat sink (FSA frame size only)
    • The USS variant (RS485) is available in the following versions:
      • Without EMC filter, with heat sink
      • With integrated EMC filter, class A/B, with heat sink
      • Without EMC filter, with flat heat sink (FSA frame size only)
      • With integrated EMC filter, class B, with flat heat sink (FSA frame size only)

    For frame size FSA, cooling is achieved through a heat sink and natural convection. Frame size FSA with flat heat sink offers space-saving and favorable heat dissipation since an additional heat sink can be installed outside the control cabinet. For frame sizes FSB and FSC, an integrated fan is used to cool the heat sink, making the compact design possible.

    The connections for all converter variants are easily accessible and in the same location. To ensure optimum electromagnetic compatibility and easy connection, the line and motor connections are located on opposite sides (as with contactors). The control terminal block does not require screws to install it.

    The optional BOP (Basic Operator Panel) can be installed without the use of tools.

    Function

    • The stress on the machine mechanical system is reduced by using a skippable frequency range to avoid resonance effects, selecting ramp-up/ramp-down times up to 650 s, using ramp smoothing as well as being able to switch the converter to a spinning motor (flying restart circuit)
    • Increased plant availability as a result of automatic restarting following a power failure or stoppage
    • Fast current limiting (FCL) for fault-free operation in the event of sudden load surges
    • Parameterizable V/f characteristic (e.g. for synchronous motors)
    • DC braking as well as compound braking for fast braking without an external braking resistor
    • DC link voltage limiting using VDC_max controller
    • Slip compensation, electronic motorized potentiometer function and three fixed speed setpoints
    • Parameterizable voltage boost for a higher dynamic performance when starting and accelerating
    • Motor holding brake function to control an external mechanical brake
    • Ordering No. for SINAMICS G110
    6SL3211-0AB11-2BA1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.12 kW; VT: 0.12 kW CT overload: 150% 60s 150x 90x 116 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0AB11-2BB1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.12 kW; VT: 0.12 kW CT overload: 150% 60s 150x 90x 116 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0AB11-2UA1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.12 kW; VT: 0.12 kW CT overload: 150% 60s 150x 90x 116 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0AB11-2UB1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.12 kW; VT: 0.12 kW CT overload: 150% 60s 150x 90x 116 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0AB12-5BA1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.25kW; VT: 0.25kW CT overload: 150% 60s 150x 90x 116 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0AB12-5BB1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.25kW; VT: 0.25kW CT overload: 150% 60s 150x 90x 116 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0AB12-5UA1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.25kW; VT: 0.25kW CT overload: 150% 60s 150x 90x 116 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0AB12-5UB1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.25kW; VT: 0.25kW CT overload: 150% 60s 150x 90x 116 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0AB13-7BA1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.37kW; VT: 0.37kW CT overload: 150% 60s 150x 90x 116 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0AB13-7BB1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.37kW; VT: 0.37kW CT overload: 150% 60s 150x 90x 116 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0AB13-7UA1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.37kW; VT: 0.37kW CT overload: 150% 60s 150x 90x 116 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0AB13-7UB1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.37kW; VT: 0.37kW CT overload: 150% 60s 150x 90x 116 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0AB15-5BA1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.55kW; VT: 0.55kW CT overload: 150% 60s 150x 90x 131 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0AB15-5BB1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.55kW; VT: 0.55kW CT overload: 150% 60s 150x 90x 131 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0AB15-5UA1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.55kW; VT: 0.55kW CT overload: 150% 60s 150x 90x 131 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0AB15-5UB1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.55kW; VT: 0.55kW CT overload: 150% 60s 150x 90x 131 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0AB17-5BA1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.75kW; VT: 0.75kW CT overload: 150% 60s 150x 90x 131 (HxWxD) Degree of protection IP20 Ambient temperature -10+40 °C without BOP without RS485 interface
    6SL3211-0AB17-5BB1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.75kW; VT: 0.75kW CT overload: 150% 60s 150x 90x 131 (HxWxD) Degree of protection IP20 Ambient temperature -10+40 °C without BOP without analog input
    6SL3211-0AB17-5UA1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.75kW; VT: 0.75kW CT overload: 150% 60s 150x 90x 131 (HxWxD) Degree of protection IP20 Ambient temperature -10+40 °C without BOP without RS485 interface
    6SL3211-0AB17-5UB1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.75kW; VT: 0.75kW CT overload: 150% 60s 150x 90x 131 (HxWxD) Degree of protection IP20 Ambient temperature -10+40 °C without BOP without analog input
    6SL3211-0AB21-1AA1 SINAMICS G110-CPM110 AC Drive, with integr. filter A 200-240V1AC+10/-10% 47-63Hz Analog input CT: 1.1kW; VT: 1.1kW CT overload: 150% 60s 160x 140x 142 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0AB21-1AB1 SINAMICS G110-CPM110 AC Drive, with integr. filter A 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 1.1kW; VT: 1.1kW CT overload: 150% 60s 160x 140x 142 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0AB21-1UA1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz Analog input CT: 1.1kW; VT: 1.1kW CT overload: 150% 60s 160x 140x 142 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0AB21-1UB1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 1.1kW; VT: 1.1kW CT overload: 150% 60s 160x 140x 142 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0AB21-5AA1 SINAMICS G110-CPM110 AC Drive, with integr. filter A 200-240V1AC+10/-10% 47-63Hz Analog input CT: 1.5kW; VT: 1.5kW CT overload: 150% 60s 160x 140x 142 (HxWxD) Degree of protection IP20 Ambient temperature -10+40 °C without BOP without RS485 interface
    6SL3211-0AB21-5AB1 SINAMICS G110-CPM110 AC Drive, with integr. filter A 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 1.5kW; VT: 1.5kW CT overload: 150% 60s 160x 140x 142 (HxWxD) Degree of protection IP20 Ambient temperature -10+40 °C without BOP without analog input
    6SL3211-0AB21-5UA1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz Analog input CT: 1.5kW; VT: 1.5kW CT overload: 150% 60s 160x 140x 142 (HxWxD) Degree of protection IP20 Ambient temperature -10+40 °C without BOP without RS485 interface
    6SL3211-0AB21-5UB1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 1.5kW; VT: 1.5kW CT overload: 150% 60s 160x 140x 142 (HxWxD) Degree of protection IP20 Ambient temperature -10+40 °C without BOP without analog input
    6SL3211-0AB22-2AA1 SINAMICS G110-CPM110 AC Drive, with integr. filter A 200-240V1AC+10/-10% 47-63Hz Analog input CT: 2.2kW; VT: 2.2kW CT overload: 150% 60s 181x 184x 152 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0AB22-2AB1 SINAMICS G110-CPM110 AC Drive, with integr. filter A 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 2.2kW; VT: 2.2kW CT overload: 150% 60s 181x 184x 152 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0AB22-2UA1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz Analog input CT: 2.2kW; VT: 2.2kW CT overload: 150% 60s 181x 184x 152 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0AB22-2UB1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 2.2kW; VT: 2.2kW CT overload: 150% 60s 181x 184x 152 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0AB23-0AA1 SINAMICS G110-CPM110 AC Drive, with integr. filter A 200-240V1AC+10/-10% 47-63Hz Analog input CT: 3.0kW; VT: 3.0kW CT overload: 150% 60s 181x 184x 152 (HxWxD) Degree of protection IP20 Ambient temperature -10+40 °C without BOP without RS485 interface
    6SL3211-0AB23-0AB1 SINAMICS G110-CPM110 AC Drive, with integr. filter A 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 3.0kW; VT: 3.0kW CT overload: 150% 60s 181x 184x 152 (HxWxD) Degree of protection IP20 Ambient temperature -10+40 °C without BOP without analog input
    6SL3211-0AB23-0UA1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz Analog input CT: 3.0kW; VT: 3.0kW CT overload: 150% 60s 181x 184x 152 (HxWxD) Degree of protection IP20 Ambient temperature -10+40 °C without BOP without RS485 interface
    6SL3211-0AB23-0UB1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 3.0kW; VT: 3.0kW CT overload: 150% 60s 181x 184x 152 (HxWxD) Degree of protection IP20 Ambient temperature -10+40 °C without BOP without analog input
    6SL3211-0KB11-2BA1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.12 kW; VT: 0.12 kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0KB11-2BB1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.12 kW; VT: 0.12 kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0KB11-2UA1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.12 kW; VT: 0.12 kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0KB11-2UB1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.12 kW; VT: 0.12 kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0KB12-5BA1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.25kW; VT: 0.25kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0KB12-5BB1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.25kW; VT: 0.25kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0KB12-5UA1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.25kW; VT: 0.25kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0KB12-5UB1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.25kW; VT: 0.25kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0KB13-7BA1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.37kW; VT: 0.37kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0KB13-7BB1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.37kW; VT: 0.37kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0KB13-7UA1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.37kW; VT: 0.37kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0KB13-7UB1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.37kW; VT: 0.37kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0KB15-5BA1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.55kW; VT: 0.55kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0KB15-5BB1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.55kW; VT: 0.55kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0KB15-5UA1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.55kW; VT: 0.55kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without RS485 interface
    6SL3211-0KB15-5UB1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.55kW; VT: 0.55kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without analog input
    6SL3211-0KB17-5BA1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.75kW; VT: 0.75kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+40 °C without BOP without RS485 interface
    6SL3211-0KB17-5BB1 SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.75kW; VT: 0.75kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+40 °C without BOP without analog input
    6SL3211-0KB17-5UA1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz Analog input CT: 0.75kW; VT: 0.75kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+40 °C without BOP without RS485 interface
    6SL3211-0KB17-5UB1 SINAMICS G110-CPM110 AC Drive, unfiltered 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.75kW; VT: 0.75kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+40 °C without BOP without analog input
PREVIOUS:SIEMENS SINAMICS V20 Basic Converters
NEXT:SIEMENS SINAMICS G120C Converters

Live chat X

Skype

WhatsApp

QQ
Email me

Mail to us

Leave a message